[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"$fGAwKV0JdX6MBMokIcJFY9JsDKrY_Hz-hiWQdG46Ydu0":3,"g5a-ex:siemens\u002Fsimatic_s7-400_cpu_firmware@*":76,"g5a-family:siemens\u002Fsimatic_s7-400_cpu_firmware":78},{"success":4,"data":5},true,{"product":6,"versions":24,"topVulnerabilitiesByEpss":29,"kevVulnerabilities":53,"seoMetadata":54,"meta":73},{"vendorName":7,"productName":8,"versionCount":9,"totalCves":9,"kevCount":10,"lastCveUpdate":11,"versions":12,"description":23},"siemens","simatic_s7-400_cpu_firmware",4,0,"2016-12-17",[13,17,19,21],{"version":14,"cve_count":15,"kev_count":10,"has_kev":16},"5.0",1,false,{"version":18,"cve_count":15,"kev_count":10,"has_kev":16},"6.0.1",{"version":20,"cve_count":15,"kev_count":10,"has_kev":16},"6.0.2",{"version":22,"cve_count":10,"kev_count":10,"has_kev":16},"6.0.3","Simatic S7-400 Cpu Firmware by Siemens is a technology product with 4 tracked versions and 4 known security vulnerabilities. Get comprehensive security analysis, vulnerability tracking, and threat intelligence for this product.",[25,26,27,28],{"version":14,"cve_count":15,"kev_count":10,"has_kev":16},{"version":18,"cve_count":15,"kev_count":10,"has_kev":16},{"version":20,"cve_count":15,"kev_count":10,"has_kev":16},{"version":22,"cve_count":10,"kev_count":10,"has_kev":16},[30,38,41,47],{"cveId":31,"description":32,"publishedDate":33,"cvssScore":34,"cvssVersion":35,"severity":36,"isKev":16,"epssScore":37},"CVE-2012-3016","Siemens SIMATIC S7-400 PN CPU devices with firmware 6 before 6.0.3 allow remote attackers to cause a denial of service (defect-mode transition and service outage) via crafted ICMP packets.","2012-07-31",7.8,"v2","High",0.03464,{"cveId":39,"description":40,"publishedDate":33,"cvssScore":34,"cvssVersion":35,"severity":36,"isKev":16,"epssScore":37},"CVE-2012-3017","Siemens SIMATIC S7-400 PN CPU devices with firmware 5.x allow remote attackers to cause a denial of service (defect-mode transition and service outage) via (1) malformed HTTP traffic or (2) malformed IP packets.",{"cveId":42,"description":43,"publishedDate":11,"cvssScore":44,"cvssVersion":45,"severity":36,"isKev":16,"epssScore":46},"CVE-2016-9158","A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN\u002FDP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN\u002FDP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 V6 and earlier CPU family (All versions), SIMATIC S7-400 V7 CPU family (All versions). Specially crafted packets sent to port 80\u002Ftcp could cause the affected devices to go into defect mode. A cold restart is required to recover the system.",7.5,"v3.0",0.03027,{"cveId":48,"description":49,"publishedDate":11,"cvssScore":50,"cvssVersion":45,"severity":51,"isKev":16,"epssScore":52},"CVE-2016-9159","A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN\u002FDP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN\u002FDP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 V6 and earlier CPU family (All versions), SIMATIC S7-400 V7 CPU family (All versions), SIMATIC S7-410 V8 CPU family (All versions), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) (All versions). An attacker with network access to port 102\u002Ftcp (ISO-TSAP) or via Profibus could obtain credentials from the PLC if protection-level 2 is configured on the affected devices.",5.9,"Medium",0.01538,[],{"title":55,"metaDescription":56,"keywords":57,"structuredData":58},"Simatic S7-400 Cpu Firmware by Siemens - Security Vulnerabilities & Analysis | EdgeProtect","Comprehensive security analysis for Simatic S7-400 Cpu Firmware by Siemens covering 4 versions with 4 tracked vulnerabilities. Real-time threat intelligence, CVE tracking, and security recommendations.","Simatic S7-400 Cpu Firmware vulnerabilities, Simatic S7-400 Cpu Firmware security, Simatic S7-400 Cpu Firmware CVE, Siemens Simatic S7-400 Cpu Firmware, Simatic S7-400 Cpu Firmware threat intelligence, Siemens security, product security analysis, cybersecurity threats, vulnerability management, CVE tracking",{"@context":59,"@type":60,"name":61,"description":56,"url":62,"manufacturer":63,"applicationCategory":67,"softwareVersion":68,"mainEntity":69},"https:\u002F\u002Fschema.org","SoftwareApplication","Simatic S7-400 Cpu Firmware","https:\u002F\u002Fedgeprotect.io\u002Fvulnerabilities\u002Ftechnologies\u002Fvendors\u002Fsiemens\u002Fsimatic_s7-400_cpu_firmware",{"@type":64,"name":65,"url":66},"Organization","Siemens","https:\u002F\u002Fedgeprotect.io\u002Fvendors\u002Fsiemens","Security Software","4 versions tracked",{"@type":70,"name":71,"description":72,"vulnerabilityCount":9,"dateModified":11},"SecurityVulnerability","Simatic S7-400 Cpu Firmware Security Vulnerabilities","Security vulnerabilities affecting Simatic S7-400 Cpu Firmware by Siemens",{"totalVersions":9,"totalVulnerabilities":9,"kevVulnerabilities":10,"lastUpdated":11,"generatedAt":74,"apiVersion":75},"2026-10-28T23:04:07.525Z","3.0",{"rows":77,"total":10,"capped":16,"failed":10},[],[]]