[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"$fy1qDMHy-lTHCfMqdhUbc8zaFIMP7Wwk8V1_7xjmfZpk":3,"g5a-ex:schneider-electric\u002Fmodicon_m340_bmxp3420302h_firmware@*":107,"g5a-family:schneider-electric\u002Fmodicon_m340_bmxp3420302h_firmware":109},{"success":4,"data":5},true,{"product":6,"versions":25,"topVulnerabilitiesByEpss":30,"kevVulnerabilities":84,"seoMetadata":85,"meta":104},{"vendorName":7,"productName":8,"versionCount":9,"totalCves":10,"kevCount":11,"lastCveUpdate":12,"versions":13,"description":24},"schneider-electric","modicon_m340_bmxp3420302h_firmware",4,16,0,"2024-02-14",[14,18,20,22],{"version":15,"cve_count":16,"kev_count":11,"has_kev":17},"2.8",1,false,{"version":19,"cve_count":11,"kev_count":11,"has_kev":17},"3.40",{"version":21,"cve_count":11,"kev_count":11,"has_kev":17},"3.50",{"version":23,"cve_count":11,"kev_count":11,"has_kev":17},"3.60","Modicon M340 Bmxp3420302h Firmware by Schneider-electric is a technology product with 4 tracked versions and 16 known security vulnerabilities. Get comprehensive security analysis, vulnerability tracking, and threat intelligence for this product.",[26,27,28,29],{"version":15,"cve_count":16,"kev_count":11,"has_kev":17},{"version":19,"cve_count":11,"kev_count":11,"has_kev":17},{"version":21,"cve_count":11,"kev_count":11,"has_kev":17},{"version":23,"cve_count":11,"kev_count":11,"has_kev":17},[31,39,47,53,57,61,65,69,72,79],{"cveId":32,"description":33,"publishedDate":34,"cvssScore":35,"cvssVersion":36,"severity":37,"isKev":17,"epssScore":38},"CVE-2014-0754","Directory traversal vulnerability in SchneiderWEB on Schneider Electric Modicon PLC Ethernet modules 140CPU65x Exec before 5.5, 140NOC78x Exec before 1.62, 140NOE77x Exec before 6.2, BMXNOC0401 before 2.05, BMXNOE0100 before 2.9, BMXNOE0110x Exec before 6.0, TSXETC101 Exec before 2.04, TSXETY4103x Exec before 5.7, TSXETY5103x Exec before 5.9, TSXP57x ETYPort Exec before 5.7, and TSXP57x Ethernet Copro Exec before 5.5 allows remote attackers to visit arbitrary resources via a crafted HTTP request.","2014-10-03",10,"v2","Critical",0.09513,{"cveId":40,"description":41,"publishedDate":42,"cvssScore":43,"cvssVersion":44,"severity":45,"isKev":17,"epssScore":46},"CVE-2017-6017","A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. A remote attacker could send a specially crafted set of packets to the PLC causing it to freeze, requiring the operator to physically press the reset button on the PLC in order to recover.","2017-06-30",7.5,"v3.0","High",0.04807,{"cveId":48,"description":49,"publishedDate":50,"cvssScore":51,"cvssVersion":44,"severity":37,"isKev":17,"epssScore":52},"CVE-2018-7241","Hard coded accounts exist in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules.","2018-04-18",9.8,0.03697,{"cveId":54,"description":55,"publishedDate":50,"cvssScore":51,"cvssVersion":44,"severity":37,"isKev":17,"epssScore":56},"CVE-2018-7761","A vulnerability exists in the HTTP request parser in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow arbitrary code execution.",0.02098,{"cveId":58,"description":59,"publishedDate":50,"cvssScore":51,"cvssVersion":44,"severity":37,"isKev":17,"epssScore":60},"CVE-2018-7242","Vulnerable hash algorithms exists in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules. The algorithm used to encrypt the password is vulnerable to hash collision attacks.",0.01884,{"cveId":62,"description":63,"publishedDate":50,"cvssScore":51,"cvssVersion":44,"severity":37,"isKev":17,"epssScore":64},"CVE-2018-7760","An authorization bypass vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. Requests to CGI functions allow malicious users to bypass authorization.",0.01469,{"cveId":66,"description":67,"publishedDate":50,"cvssScore":43,"cvssVersion":44,"severity":45,"isKev":17,"epssScore":68},"CVE-2018-7762","A vulnerability exists in the web services to process SOAP requests in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow result in a buffer overflow.",0.01291,{"cveId":70,"description":71,"publishedDate":50,"cvssScore":43,"cvssVersion":44,"severity":45,"isKev":17,"epssScore":68},"CVE-2018-7759","A buffer overflow vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. The buffer overflow vulnerability is caused by the length of the source string specified (instead of the buffer size) as the number of bytes to be copied.",{"cveId":73,"description":74,"publishedDate":75,"cvssScore":76,"cvssVersion":77,"severity":45,"isKev":17,"epssScore":78},"CVE-2022-45789","A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus functions on the controller when hijacking an authenticated Modbus session. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU - part numbers BMXP34* (All Versions), Modicon M580 CPU - part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety - part numbers BMEP58*S and BMEH58*S (All Versions)\n\n","2023-01-31",8.1,"v3.1",0.01101,{"cveId":80,"description":81,"publishedDate":82,"cvssScore":51,"cvssVersion":77,"severity":37,"isKev":17,"epssScore":83},"CVE-2022-37300","A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Including all Unity Pro versions (former name of EcoStruxure Control Expert) (V15.0 SP1 and prior), EcoStruxure Process Expert, Including all versions of EcoStruxure Hybrid DCS (former name of EcoStruxure Process Expert) (V2021 and prior), Modicon M340 CPU (part numbers BMXP34*) (V3.40 and prior), Modicon M580 CPU (part numbers BMEP* and BMEH*) (V3.20 and prior).","2022-09-12",0.00915,[],{"title":86,"metaDescription":87,"keywords":88,"structuredData":89},"Modicon M340 Bmxp3420302h Firmware by Schneider-electric - Security Vulnerabilities & Analysis | EdgeProtect","Comprehensive security analysis for Modicon M340 Bmxp3420302h Firmware by Schneider-electric covering 4 versions with 16 tracked vulnerabilities. Real-time threat intelligence, CVE tracking, and security recommendations.","Modicon M340 Bmxp3420302h Firmware vulnerabilities, Modicon M340 Bmxp3420302h Firmware security, Modicon M340 Bmxp3420302h Firmware CVE, Schneider-electric Modicon M340 Bmxp3420302h Firmware, Modicon M340 Bmxp3420302h Firmware threat intelligence, Schneider-electric security, product security analysis, cybersecurity threats, vulnerability management, CVE tracking",{"@context":90,"@type":91,"name":92,"description":87,"url":93,"manufacturer":94,"applicationCategory":98,"softwareVersion":99,"mainEntity":100},"https:\u002F\u002Fschema.org","SoftwareApplication","Modicon M340 Bmxp3420302h Firmware","https:\u002F\u002Fedgeprotect.io\u002Fvulnerabilities\u002Ftechnologies\u002Fvendors\u002Fschneider-electric\u002Fmodicon_m340_bmxp3420302h_firmware",{"@type":95,"name":96,"url":97},"Organization","Schneider-electric","https:\u002F\u002Fedgeprotect.io\u002Fvendors\u002Fschneider-electric","Security Software","4 versions tracked",{"@type":101,"name":102,"description":103,"vulnerabilityCount":10,"dateModified":12},"SecurityVulnerability","Modicon M340 Bmxp3420302h Firmware Security Vulnerabilities","Security vulnerabilities affecting Modicon M340 Bmxp3420302h Firmware by Schneider-electric",{"totalVersions":9,"totalVulnerabilities":10,"kevVulnerabilities":11,"lastUpdated":12,"generatedAt":105,"apiVersion":106},"2026-11-28T11:15:20.675Z","3.0",{"rows":108,"total":11,"capped":17,"failed":11},[],[]]